Key 1
Set Delta Volts
Press key 1 to set the DELTA VOLTS, use the scroll keys to increase or decrease the Delta voltage. When you have selected the value required press the 0 key to enter the value. The default value is 0.18volts.
When a battery is being charged the voltage across the battery increases until it reaches the fully charged state. At this point the voltage begins to drop, this voltage drop is referred to as the negative delta voltage. When the pack voltage falls by the amount programmed in the DELTA VOLTS charging is stopped. The higher the voltage set in DELTA VOLTS the warmer the pack will be before switch off.
Delta Volts
0.18Click here to return
Pressing the # key would increase the Delta Volts
Pressing the * key would decrease the Delta Volts
Pressing the 0 key would enter the value selected
* 0 #
Key 2
Auto Start Time
Press key 2 to set an AUTOMATIC START TIME. The delay can be scrolled up or down using the scroll keys then entered by pressing the 0 key. Now run through the charge menus selecting the type of charge required and press 0 to start charge. The display will show the delay time counting down, when the timer reaches zero charging will be started.
Auto start is a programmable delay before charging will begin. Ideal for race meetings where you know when you have to start charging your pack. With Auto Start you can set it and have a wander round the pits, knowing that there is no panic to get back to charge your pack for the next heat.
Autostart Time
45 minutesClick here to return
Pressing the # key would increase the Auto Start Time.
Pressing the * key would decrease the Auto Start Time.
Pressing the 0 key would enter the value selected
* 0 #
Key 3
Repeak Timer
Repeak time is a programmable time between the end of a charge and re-peaking the pack.
The delay can be scrolled up or down using the scroll keys, when the required value is displayed pressing the 0 key will enter this value. Set a value for the repeak current using the scroll keys, when the required value is displayed press the 0 key to accept it. Then set a delta fallback voltage for the re-peak
If charging is now selected the pack will be charged then rested while the repeak timer counts down to zero at which time repeak of the pack will take place. The default delta fallback for repeak is set to 0.10 volts.
Repeak Time
5 minutesClick here to return
Pressing the # key would increase the Repeak Timer.
Pressing the * key would decrease the Repeak Timer.
Pressing the 0 key would enter the value selected
* 0 #
Key 4
View Menu
Press key 4 to select the VIEW MENU . Use the scroll keys to scroll through the menu (displayed on right-hand side of front panel) If the remote leads are connected then pressing 0 will show the values for all 6 individual cells, pressing 0 again will return you to the view menu.
Time
Pack Volts342
9.12Click here to return
Pressing key 4 will display the View Menu.
Pressing the # key will scroll down through the menu
Pressing the * key will scroll up through the menu
If the remote leads are fitted to the cells, then pressing
key 0 would display the selected data on all 6 cells
* 0 # NOTE:- Calculated values are only displayed at end of operation. (K/joules, capacity)
Key 5
Time/Volts/Amps
Press key 5 to set the charge current (default 4.5 amps). Use the scroll keys to increase or decrease in 500mA steps. Press key 0 when the display shows the required current. You can change the charge current whilst Pro-Trak is charging.
Set Current
4.50Click here to return
Pressing the # key would increase the Charge Amps.
Pressing the * key would decrease the Charge Amps.
Pressing the 0 key would enter the value selected
* 0 #
Key 6
Back Light
1.54 1.56 1.68 1.54 1.86 1.53 The back lit display allows easy reading of information in poor light conditions.
1.54 1.56 1.68 1.54 1.86 1.53
Key 7
Escape/Abort
|
Click here to return Pressing key 7 once would escape from a menu, pressing it 3 times would abort Charge/Discharge operation If held down would return to main menu |
|||
|
Key 8
Select Number of Cells
Pressing key 8 will display number of cells to charge/discharge, scroll up or down using the scroll keys. When entered, the charge delta and the discharge cut off will be set for the number of cells selected.
Cells
6Delta
0.18Click here to return
Pressing the # key would increase the Number of cells and
increase the delta volts accordingly.
Pressing the * key would decrease the Number of cells and
decrease the delta volts accordingly.
Pressing the 0 key would enter the value selected
* 0 #
Key 9
Set Discharge Amps
SET DISCHARGE CURRENT FOR CALCULATION OF DISCHARGE TIME
Discharge Amps
22Click here to return
Pressing the # key would increase the Discharge calculation figure.
Pressing the * key would decrease the Discharge calculation figures.
Pressing the 0 key would enter the value selected
* 0 #
Key 0
Enter/Start
Pressing key 0 will either ENTER a value, START a FUNCTION or DISPLAY all 6 cells on screen.
|
Click here to return Pressing key 0 would enter the value selected or if a function is selected (i.e., charge or discharge ) would start that function |
|||
|
Key *
Scroll Up
|
Click here to return Use * key to scroll up through menu's |
|||
|
Key#
Scroll Down
|
Click here to return Use # key to scroll down through menu's |
|||
|
VIEW MENU DESCRIPTION Time 363 Run time charging/discharging Pack Volts 7.23 Voltage of pack (real time) Peak Volts 9.76 Highest voltage reached by pack during charge Fallback Volts 0.18 Calculated fallback voltage of pack (peak minus end volts) End Volts 9.58 Voltage of pack at switch off Start Volts 8.12 Voltage of pack 20 seconds after starting charge/discharge Average Volts 6.78 Average voltage of pack Capacity 2056 Capacity of pack calculated at end of charge/discharge K/Joules 60.12 K/Joules of pack calculated at end of discharge Power % 104 Calculated power (punch) of the pack, 100 % being a club pack. (return ) All data in the View Menu is pack data. Pressing the 0 key will display the selected data of all 6 cells. Pressing 0 again will return to the View Menu.
Battery Management System (return)
Pro-Trak is one of the only systems that comes complete ready to monitor each cell in a pack, this allows you to maintain your packs in peak condition.Heatsink
To dissipate the heat generated during discharge, Pro-Trak is fitted with a double heatsink.To further improve the heat dissipation the unit is fitted with a integral fan.LCD Display (return)
This is a 2 line * 16 character back lit display.
The 2 lines allow the unit to display input volts, pack volts and delta fallback on the top line, and charge time, charge current and input capacity on the bottom line.
12.35 9.34 0.00 23:34 4.50 1356 If the remote leads are fitted then the display can give information on all the cells in the pack at any time. This allows you to view all the cells during charging, discharging or while the pack is just standing doing nothing!
cell 1 cell 2 cell 3
1.54 1.56 1.68 1.54 1.86 1.53
cell 4 cell 5 cell 6 During charge the display above would indicate that maybe there is a problem with cell 5.
Charger/Discharger/cycler (return )
Pro-Trak will charge discharge or cycle cells
It can cycle cells up to 99 times in one operation
You can enter a delay between cycles to allow the cells to cool before the next cycle.
You can also connect Pro-Trak to a computer to graph the results or connect
to a serial printer to print the results after each operation.
(See graph information from the main menu)
Temperature Detect (return )
With the addition of a temperature detect module (TDM) Pro-Trak can monitor the temperature of the cells and terminate discharge when the cells reach a temperature that you decide.We have found that temperature charging is more reliable as the delta voltages to determine full charge can vary considerably between packs and manufactures.
(See temperature module information from the main menu)
20 Amp Discharge (return )
Pro-Trak is a true 20 amp discharge.
This is fixed at 20 amps, but Pro-Trak can calculate what the discharge time would have been between
10 and 30 amps from the 20 amp discharge time.Peak Detect
With it's unique discharge before charge facility Pro-Trak can safely charge Ni-Mh cells (Ni-Mh cells have a faulse peak problem when cold) without false peaking. When discharge before charge is selected a lockout of 1000mA is used to ignore false peaks.
Ni-Mh and Ni-Cd cells
Pro-Trak allows you to program a separate delta for Ni-Mh and Ni-Cd cells. You just select what type of cells you are charging and the correct delta is used.