Pro-Trak is one of the most advanced battery management systems in the world and we are sure that it will give you excellent service.

Pro-Trak has been designed specifically for the serious radio race car owner who wants to ensure that the batteries that power his/her car are in peak condition.

Pro-Trak combines all the functions you need, charger, discharger, cycler all in one easy to use compact unit

 

FEATURE LIST

Microprocessor Controlled For superb accuracy and reliability through reduced component count
LCD display 2 line x 16 character Two lines of text to display data/text messages
Wide angle transflective display Superb contrast for visibility in bright sunlight
Switchable LED backlight Enables reading of display in poor light (tent etc)
Built in cooling fan Reliability further enhanced by the inclusion of cooling fan
Constant Current Discharge Fixed precision constant current discharge 20 amp

 

PROGRAMMABLE FEATURES

Delta Voltage Fallback voltage of pack, point at which charging will be stopped
Auto start Time Delay time before charging will start
Repeak Timer Delay after charge before a repeak will take place
Repeak Current Current at which pack will be Repeaked
Discharge cut-off Voltage that capacity of the pack is calculated at during discharge.
Charge current Keyboard adjustable from 2 - 9 amps ( depending on power supply )

 

CHARGE MODES

Charge Charge 1 - 6 cells (7 cells with input of 14 volts)
 Linear Constant current charge
 Soft pulse Linear charge with a rest period of 50 mS every 250 mS
 Profile Linear charge to 9 volts then change to repulse to finish charge
 Repulse Linear charge but includes a rest period and discharge pulse
 Push Charge Increases performance of cells
 Tx charge Softpulse charges at 2 amps for 3 minutes  This is for emergency charging only, if you find your transmitter flat just before your race Pro-Trak can put enough charge into the cells in 3 minutes for you to be able to race your heat. Pro-Trak can not charge 8 cells fully from 12 volt supply.

DISCHARGE

Discharge Discharge 1 - 6 cells
Programmable discharge calculation Calculate discharge time at any rate between 10 and 30 amps
Programable cut-of voltage Set cut-off from 1 - 6 volts

DISPLAY FUNCTIONS (information on all 6 cells in the pack)

Charge current Input current to pack
Charge Time for pack/cell Time pack and each cell has taken to charge
Charge Capacity for pack/cell Input capacity of pack and each cell
Peak Volts for pack/cell Peak voltage that pack/cell reached during charge
End Volts for pack/cell Voltage that pack/cell fell to when charging stopped
Fallback for pack/cell Calculated fallback of pack/cell ie, peak volts minus end volts
Discharge Time for pack/cell Time pack/cells has taken to discharge
Discharge Capacity for pack/cell Capacity of pack/cells
Kilo joules for pack/cell Calculated Kilo joule reading of pack/cell using time, current, average voltage
Power % Calculated from internal resistance ( punch of pack/cell )
All 6 cells visible on LCD display Display information on all 6 cells at same time on screen ie, volts/time/capacity

 

MISCELLANEOUS FEATURES

RS232 output to printer Pro-Trak will output to a serial printer (RS232 ) or a computer
Menu driven display EASY menu driven display of data ( or quick access via HOT KEYS )
Charger/Discharger/Cycler Pro-Trak can be programmed to charge, repeak if required then discharge and
send data to printer/computer
IBM graph program Software to enable Pro-Trak to plot graphs of all 6 cells


ADVANTAGES OF USING Pro-Trak

What really makes Pro-Trak unique is that it provides the advantages of individual cell monitoring during charging and discharging without having to unsolder the cells from the pack.

Most chargers on the market detect when a pack is charged by monitoring either its temperature or the negative delta peak.

However the major advantage that Pro-Trak has over these is the ability to charge the pack while monitoring the condition of each cell individually.

For example a charger charges the pack and switches off when the pack reaches the negative delta fallback level. However unless the pack is very well matched some cells may not have been charged fully and other cells may have been overcharged. In other words you may think your pack is OK when in reality you don't know and there is no way of finding out.

With Pro-Trak this situation is easily detected and the mismatched cells identified.

The same applies when discharging. Although the pack may be discharged to the correct level. It is quite possible for some cells to be discharged to the point that they actually reverse polarity. This situation is not only damaging to the reversed cell but can also damage the other cells in the pack.

Pro-Trak will never allow this condition to occur, as soon as a cell is detected falling below 0.10 volts the discharge is stopped. In addition Pro-Trak actually identifies the cause of the problem., (remote leads must be fitted for Pro-Trak to detect cells falling to 0.1 volts).

Finally no longer will you have to unsolder your cells in order to test them. Unsoldering cells can lead to premature damage. Really the only time you should unsolder cells is to remove/replace faulty ones. With Pro-Trak you can test the cells while connected as a pack.